電(dian)線(xian)(xian)(xian)幾(ji)平(ping)方(fang)是國家標(biao)(biao)準(zhun)規定(ding)的(de)的(de)一個標(biao)(biao)稱值,電(dian)線(xian)(xian)(xian)的(de)平(ping)方(fang)實際上標(biao)(biao)的(de)是電(dian)線(xian)(xian)(xian)的(de)橫截面(mian)積,即(ji)電(dian)線(xian)(xian)(xian)圓形橫截面(mian)的(de)面(mian)積,單位為平(ping)方(fang)毫米。是用戶(hu)根據電(dian)線(xian)(xian)(xian)電(dian)纜的(de)負荷來選擇電(dian)線(xian)(xian)(xian)電(dian)纜。
那(nei)電(dian)線(xian)怎(zen)么(me)看平(ping)方數(shu)的呢?電(dian)線(xian)的平(ping)方是怎(zen)么(me)計算?
電線的規格在國際上常(chang)用(yong)的有(you)三(san)個標準:分別是美制(AWG)、英制(SWG)和(he)我們的(CWG)。
Q電線怎么看平方數(shu)?A
幾(ji)(ji)平(ping)(ping)方是(shi)國家標準規定的的一(yi)個(ge)標稱值,幾(ji)(ji)平(ping)(ping)方是(shi)用(yong)戶(hu)根(gen)據電(dian)線(xian)電(dian)纜的負(fu)荷(he)來(lai)選擇電(dian)線(xian)電(dian)纜。電(dian)線(xian)平(ping)(ping)方數是(shi)裝修水(shui)電(dian)施工中的一(yi)個(ge)口(kou)頭用(yong)語,常說的幾(ji)(ji)平(ping)(ping)方電(dian)線(xian)是(shi)沒(mei)加單位,即平(ping)(ping)方毫米。
電線的平方(fang)實際(ji)上(shang)標(biao)的是電線的橫截面(mian)(mian)積,即(ji)電線圓形(xing)橫截面(mian)(mian)的面(mian)(mian)積,單位為平方(fang)毫米(mi)。
1、整捆的(de)新線(xian),包裝表面會有線(xian)的(de)標(biao)簽,清楚(chu)標(biao)注線(xian)的(de)品牌、型號、線(xian)徑(電線(xian)的(de)平方數(shu))
2、有些大(da)品牌的(de)電線(xian)在絕緣層上印有品牌、型號、線(xian)徑(電線(xian)的(de)平方數(shu))。
3、對于沒(mei)有(you)標注的(de)電(dian)線,經驗(yan)豐富的(de)電(dian)工可以(yi)通過目(mu)測,看出(chu)電(dian)線的(de)平方數。
4、沒有經驗的(de)人,如(ru)果要判斷電(dian)線(xian)的(de)粗細(平方),可用游標尺測量電(dian)線(xian)的(de)直徑,然后求出截面。
如果(guo)要(yao)判(pan)斷電線的粗細(平方(fang)),可用游標尺測量(liang)電線的直(zhi)徑,然后求出截面。
截面的計算公(gong)式:S=半徑(jing)的平方R×π(R為(wei)電(dian)線的半徑(jing))
比如直(zhi)徑(jing)1.76的(de)線(xian),就是1.76÷2×3.14=2.76平方≈2.5平方,(取近似值)。
如果你是要選擇電(dian)線的大小,一般是先根(gen)據(ju)用電(dian)器的功率大小算出電(dian)流(liu),然后(hou)根(gen)據(ju)電(dian)流(liu)在查電(dian)工手(shou)冊即可(ke),這樣(yang)比較準確。
如果是單芯的(de)(de)(de)就(jiu)(jiu)(jiu)可(ke)以(yi)量一下其(qi)直徑,然后得出半徑根據面積的(de)(de)(de)公式S=半徑*半徑*3.14,就(jiu)(jiu)(jiu)可(ke)以(yi)知道(dao)該電線的(de)(de)(de)橫截面積,而(er)有些線是由多(duo)條(tiao)線芯組合扭在一起的(de)(de)(de),這樣就(jiu)(jiu)(jiu)不能用單芯的(de)(de)(de)方法去(qu)算(suan)了,只能是按(an)這條(tiao)電線中多(duo)條(tiao)線的(de)(de)(de)其(qi)中一條(tiao)去(qu)接單芯線算(suan),然后再乘以(yi)線的(de)(de)(de)股數就(jiu)(jiu)(jiu)可(ke)以(yi)。
公式(shi)為S=半徑*半徑*3.14*N,其中N為扭(niu)成這條(tiao)電線的(de)數量(liang)!
Q電線電纜的平方(fang)計算方(fang)式(shi)A
一般(ban)來(lai)說,經(jing)驗載(zai)電(dian)量(liang)是當電(dian)網電(dian)壓是220V時候(hou),每(mei)平(ping)方(fang)(fang)(fang)電(dian)線(xian)(xian)的(de)經(jing)驗載(zai)電(dian)量(liang)是一千(qian)瓦(wa)(wa)左右(you)。銅(tong)(tong)線(xian)(xian)每(mei)個(ge)平(ping)方(fang)(fang)(fang)可以載(zai)電(dian)1-1.5千(qian)瓦(wa)(wa),鋁線(xian)(xian)每(mei)個(ge)平(ping)方(fang)(fang)(fang)可載(zai)電(dian)0.6-1千(qian)瓦(wa)(wa)。因此功率為1千(qian)瓦(wa)(wa)的(de)電(dian)器(qi)只(zhi)需用一平(ping)方(fang)(fang)(fang)的(de)銅(tong)(tong)線(xian)(xian) 就足夠(gou)了。具體到(dao)電(dian)流(liu),短距送電(dian)時一般(ban)銅(tong)(tong)線(xian)(xian)每(mei)平(ping)方(fang)(fang)(fang)可載(zai)3A到(dao)5A的(de)電(dian)流(liu)。散熱(re)條件好(hao)取(qu)5A/平(ping)方(fang)(fang)(fang)毫米,不(bu)好(hao)取(qu)3A/平(ping)方(fang)(fang)(fang)毫米。
換算方法:
知道電線(xian)的平(ping)方,計(ji)算(suan)電線(xian)的半徑用求圓形面積的公式計(ji)算(suan):
電(dian)線(xian)平方(fang)數(shu)(平方(fang)毫米)=圓周(zhou)率(3.14)×電(dian)線(xian)半徑(毫米)的平方(fang)
知(zhi)道電線(xian)的(de)(de)平方,計算(suan)線(xian)直徑(jing)也是(shi)這樣(yang),如:2.5方電線(xian)的(de)(de)線(xian)直徑(jing)是(shi):2.5÷ 3.14 = 0.8,再(zai)開方得出(chu)0.9毫米(mi),因(yin)此2.5方線(xian)的(de)(de)線(xian)直徑(jing)是(shi):2×0.9毫米(mi)=1.8毫米(mi)。
知道電線的直徑,計(ji)(ji)算電線的平方也用求圓形面(mian)積的公(gong)式來計(ji)(ji)算:
電線的平方(fang)=圓周率(3.14)×線直徑的平方(fang)/4
電(dian)纜(lan)大(da)小也用平(ping)方標稱,多股線就是每(mei)根導線截面積(ji)之和(he)。
電纜截面積的(de)計(ji)算公式:0.7854 × 電線(xian)(xian)直(zhi)徑(jing)(jing)(毫米)的(de)平(ping)(ping)方 × 股數如48股(每(mei)股電線(xian)(xian)直(zhi)徑(jing)(jing)0.2毫米)1.5平(ping)(ping)方的(de)線(xian)(xian):0.7854 ×(0.2 × 0.2)× 48 = 1.5平(ping)(ping)方
Q電線平方數和電流的換算關(guan)系A
2.5平方(fang)毫米(mi)銅電源線的安(an)全載流量——28A。
4平(ping)方毫米銅電源(yuan)線的安(an)全載流量——35A。
6平方毫米銅電源線的(de)安全載(zai)流量——48A。
10平方毫(hao)米銅電(dian)源線(xian)的安全載流量——65A。
16平方毫米銅電(dian)源線(xian)的安全載流量——91A.
25平方(fang)毫米銅(tong)電源線的(de)安全(quan)載(zai)流量——120A。
如果是鋁(lv)線,線徑要取銅(tong)線的(de)1.5-2倍。
如果銅(tong)線(xian)電流小于28A,按每平方毫米10A來取肯定安(an)全。
如果銅線電流大于120A,按每平方毫米5A來取。
Q電線電纜計算口訣A
電線的平方可以用電線的直徑測量計算,因為電線直徑較好測量,2.5平方適用于民用照明、4平方用于室內插座、6平方用于即熱型熱水器。
公式是S=3.14d/4;d是直徑
鋁芯絕緣導(dao)線載流量與(yu)截面的倍數關系(xi)
截面:1 1.5 2.5 4 6 10 16 25 35 50 70 95 120
倍數:9 9 9 8 7 6 5 4 3.5 3 3 2.5 2.5
電(dian)流:9 14 23 32 48 60 90 100 123 150 210 238 300
估算口訣:
十下五,百上二(er)(er),二(er)(er)五三(san)五四(si)三(san)界,
七零九(jiu)(jiu)五兩(liang)倍半,穿(chuan)管溫度八九(jiu)(jiu)折,
銅線升(sheng)級(ji)算,裸線加(jia)一半。
【簡單活學活用】
用這個電工口訣來算:十下五,百上二,二五三五四三界,七零九五兩倍半,穿管溫度八九折,銅線升級算。舉個例子:電線的平方數:1、1.5、 2.5、 4、 6、 10、 16、 25、 35、 50、 70、 95、 120、 150、 185……口訣中:
“十(shi)下五”,指的是10平(ping)方以下的可(ke)以流過五倍電流值
“百上(shang)二”,指的(de)(de)是(shi)100平方以上(shang)的(de)(de)線可以流(liu)(liu)過兩倍的(de)(de)電流(liu)(liu)值
“二五三(san)五四三(san)界”指的(de)是25平方以下10平方以上的(de)線可(ke)以流過四倍(bei)的(de)電流,35平方以上50平方以下的(de)線可(ke)以流過三(san)倍(bei)的(de)電流。
“七零九五兩倍(bei)半”指的(de)是(shi)70平方、95平方的(de)線可以(yi)流(liu)過2.5倍(bei)的(de)電(dian)流(liu)。
以(yi)上口訣(jue)是(shi)根據鋁(lv)線來算(suan)的(de)(de),“銅線升(sheng)級算(suan)”指的(de)(de)是(shi)比如我(wo)選用了4平方(fang)的(de)(de)鋁(lv)線,流(liu)過的(de)(de)電流(liu)應該是(shi)20A,換(huan)成銅線就可以(yi)用2.5平方(fang)的(de)(de)線來代替。
Q導線截面(mian)積與載流量的計算A
一、一般(ban)銅導線(xian)(xian)載流量導線(xian)(xian)的安全載流量是根據所允許的線(xian)(xian)芯最高(gao)溫度、冷卻(que)條件、敷設條件來(lai)確定的。一般(ban)銅導線(xian)(xian)的安全載流量為5~8A/mm2,鋁導線(xian)(xian)的安全載流量為3~5A/mm2。
[關鍵(jian)點]一(yi)般銅導線的安(an)全載流量為5~8A/mm2,鋁(lv)導線的安(an)全載流量為3~5A/mm2。
如(ru):
2.5mm2BVV銅導線安全載流量的推薦(jian)值2.5×8A/mm2=20A4mm2BVV
銅導線安全載流量(liang)的推(tui)薦值4×8A/mm2=32A。
二、計算銅導線(xian)截面(mian)積利用(yong)銅導線(xian)的(de)安(an)全載流(liu)量(liang)的(de)推薦值5~8A/mm2,
計(ji)算出所選取銅導線截面積S的上下范圍:
S=[I/(5~8)]=0.125I~0.2I(mm2)
S——銅(tong)導(dao)線(xian)截面積(mm2)
I——負載電流(A)
三、功(gong)率計算(suan)一(yi)般(ban)負(fu)載(zai)(zai)(zai)(也可以(yi)成為(wei)用電(dian)(dian)(dian)器,如(ru)點燈、冰箱等等)分為(wei)兩種(zhong),一(yi)種(zhong)式(shi)電(dian)(dian)(dian)阻(zu)性(xing)負(fu)載(zai)(zai)(zai),一(yi)種(zhong)是電(dian)(dian)(dian)感性(xing)負(fu)載(zai)(zai)(zai)。
對于(yu)電(dian)(dian)(dian)阻性負(fu)載(zai)(zai)(zai)的計算公(gong)(gong)(gong)(gong)(gong)式:P=UI,對于(yu)日光(guang)燈負(fu)載(zai)(zai)(zai)的計算公(gong)(gong)(gong)(gong)(gong)式:P=UIcosф,其中日光(guang)燈負(fu)載(zai)(zai)(zai)的功率(lv)因數(shu)(shu)cosф=0.5,不同(tong)電(dian)(dian)(dian)感(gan)性負(fu)載(zai)(zai)(zai)功率(lv)因數(shu)(shu)不同(tong),統(tong)一(yi)計算家庭用(yong)電(dian)(dian)(dian)器(qi)時可以將功率(lv)因數(shu)(shu)cosф取0.8,也(ye)就是(shi)說(shuo)(shuo)如(ru)果一(yi)個(ge)(ge)家庭所(suo)有用(yong)電(dian)(dian)(dian)器(qi)加上總(zong)功率(lv)為6000瓦(wa),則最(zui)大(da)電(dian)(dian)(dian)流(liu)是(shi)I=P/Ucosф=6000/220*0.8=34(A),但是(shi),一(yi)般情(qing)況下(xia),家里(li)的電(dian)(dian)(dian)器(qi)不可能同(tong)時使用(yong),所(suo)以加上一(yi)個(ge)(ge)公(gong)(gong)(gong)(gong)(gong)用(yong)系數(shu)(shu),公(gong)(gong)(gong)(gong)(gong)用(yong)系數(shu)(shu)一(yi)般0.5,所(suo)以,上面的計算應該改寫(xie)成:I=P*公(gong)(gong)(gong)(gong)(gong)用(yong)系數(shu)(shu)/Ucosф=6000*0.5/220*0.8=17(A),也(ye)就是(shi)說(shuo)(shuo),這個(ge)(ge)家庭總(zong)的電(dian)(dian)(dian)流(liu)值(zhi)為17A。則總(zong)閘空(kong)氣開關(guan)不能使用(yong)16A,應該用(yong)大(da)于(yu)17A的。
Q電線截(jie)面(mian)積與安全載(zai)流量的計(ji)算A
一、一般銅(tong)導(dao)(dao)線(xian)載(zai)(zai)流(liu)量(liang)導(dao)(dao)線(xian)的(de)(de)安全(quan)(quan)載(zai)(zai)流(liu)量(liang)是根(gen)據所允許的(de)(de)溫度(du)、冷卻(que)條件、敷(fu)設條件來確定的(de)(de)。一般銅(tong)導(dao)(dao)線(xian)的(de)(de)安全(quan)(quan)載(zai)(zai)流(liu)量(liang)為(wei)5~8A/mm2,鋁導(dao)(dao)線(xian)的(de)(de)安全(quan)(quan)載(zai)(zai)流(liu)量(liang)為(wei)3~5A/mm2。
[關鍵(jian)點(dian)]一(yi)般銅導線(xian)的安全(quan)載(zai)(zai)流(liu)量(liang)為5~8A/mm2,鋁導線(xian)的安全(quan)載(zai)(zai)流(liu)量(liang)為3~5A/mm2。
如:
2.5mm2BVV銅導線安全載流(liu)量的推薦值2.5×8A/mm2=20A4mm2BVV
銅導線安全(quan)載流量(liang)的推薦值4×8A/mm2=32A
二、計算(suan)銅(tong)導(dao)線截(jie)面(mian)積(ji)利用銅(tong)導(dao)線的安全(quan)載(zai)流量的推薦值5~8A/mm2,計算(suan)出所選取(qu)銅(tong)導(dao)線截(jie)面(mian)積(ji)S的上(shang)下范(fan)圍:
S==0.125I~0.2I(mm2)
S——銅導線(xian)截面積(mm2)
I——負載電(dian)流(A)
三、功(gong)率計算一般負載(zai)(也(ye)可以成為用(yong)電器,如點燈、冰箱等等)分(fen)為兩種(zhong),一種(zhong)式電阻性(xing)負載(zai),一種(zhong)是電感性(xing)負載(zai)。
對于電阻性(xing)負載(zai)的(de)(de)(de)計(ji)(ji)算(suan)公式:P=UI,對于日光燈(deng)負載(zai)的(de)(de)(de)計(ji)(ji)算(suan)公式:P=UIcosф,其(qi)中日光燈(deng)負載(zai)的(de)(de)(de)功率(lv)因(yin)數(shu)(shu)(shu)cosф=0.5,不(bu)同電感性(xing)負載(zai)功率(lv)因(yin)數(shu)(shu)(shu)不(bu)同,統一(yi)(yi)計(ji)(ji)算(suan)家庭用(yong)電器(qi)時(shi)可以將功率(lv)因(yin)數(shu)(shu)(shu)cosф取0.8,也(ye)就(jiu)是(shi)說如果一(yi)(yi)個(ge)家庭所有用(yong)電器(qi)加上總功率(lv)為6000瓦,則最(zui)大電流是(shi)I=P/Ucosф=6000/220×0.8=34(A),但(dan)是(shi),一(yi)(yi)般(ban)情況(kuang)下,家里的(de)(de)(de)電器(qi)不(bu)可能同時(shi)使(shi)用(yong),所以加上一(yi)(yi)個(ge)公用(yong)系(xi)數(shu)(shu)(shu),公用(yong)系(xi)數(shu)(shu)(shu)一(yi)(yi)般(ban)0.5,所以,上面(mian)的(de)(de)(de)計(ji)(ji)算(suan)應該改寫(xie)成I=P×公用(yong)系(xi)數(shu)(shu)(shu)/Ucosф=6000×0.5/220×0.8=17(A),也(ye)就(jiu)是(shi)說,這(zhe)個(ge)家庭總的(de)(de)(de)電流值(zhi)為17A,則總閘空(kong)氣(qi)開關不(bu)能使(shi)用(yong)16A,應該用(yong)大于17A的(de)(de)(de)。
估算口(kou)訣(jue):
二(er)點五下乘以九(jiu),往上減一順(shun)號(hao)走。
三(san)十五(wu)乘三(san)點五(wu),雙雙成組減(jian)點五(wu)。
條件有變加折(zhe)算,高溫九折(zhe)銅升級(ji)。
穿管根數二三(san)四,八(ba)七六折(zhe)滿載流(liu)。
其實(shi)電(dian)(dian)(dian)(dian)線(xian)也可(ke)以稱呼它的(de)(de)(de)直(zhi)徑(jing)的(de)(de)(de),比(bi)如(ru)1平(ping)方(fang)的(de)(de)(de)也可(ke)稱直(zhi)徑(jing)1.13mm,1.5平(ping)方(fang)的(de)(de)(de)也可(ke)說是1.37(mm直(zhi)徑(jing))。因為選用(yong)電(dian)(dian)(dian)(dian)線(xian)時(shi)主要考慮(lv)電(dian)(dian)(dian)(dian)線(xian)使用(yong)時(shi)會不會嚴發熱(re)造成(cheng)事故,電(dian)(dian)(dian)(dian)線(xian)的(de)(de)(de)(截面(mian)積)平(ping)方(fang)數與通過的(de)(de)(de)電(dian)(dian)(dian)(dian)流安(an)培數有直(zhi)接對應的(de)(de)(de)倍(bei)數關(guan)系,計(ji)算起來很簡單方(fang)便。比(bi)如(ru)一平(ping)方(fang)銅電(dian)(dian)(dian)(dian)線(xian)流過6A電(dian)(dian)(dian)(dian)流是安(an)全的(de)(de)(de),不會嚴重發熱(re)。如(ru)2.5平(ping)方(fang)銅電(dian)(dian)(dian)(dian)線(xian)就是6A*2.5=15A,就這么(me)簡單地算出(chu)來這2.5平(ping)方(fang)通過15A電(dian)(dian)(dian)(dian)流是安(an)全的(de)(de)(de),如(ru)用(yong)直(zhi)徑(jing)計(ji)算就麻煩多了。
Q如何判(pan)斷電纜(lan)的平方數(shu)是否達標A
不管是電纜和電線,可以按(an)照一下兩(liang)種(zhong)方(fang)法來(lai)判斷:
1、對于實心(xin)圓(yuan)導體
用(yong)千分尺測量(liang)導體直徑d,單(dan)位:mm。按照圓(yuan)面(mian)積公式計算(suan),即(ji):S=π*d^2/4 (mm^2)
2、對于多股單線絞合(he)導體
a、非緊壓導體
可采取抽取一(yi)根或多根單(dan)線用千分尺(chi)測量直(zhi)徑(jing),計(ji)算出平均單(dan)線直(zhi)徑(jing)d,單(dan)位:mm。
按(an)照圓面(mian)(mian)積公式(shi)(shi)計算出(chu)平均(jun)單(dan)線(xian)(xian)截面(mian)(mian),再將單(dan)線(xian)(xian)平均(jun)截面(mian)(mian)積乘(cheng)以總(zong)根(gen)數,就能得(de)出(chu)實際(ji)電纜導體(ti)的截面(mian)(mian)積,即:S=(π*d^2/4 )*n (mm^2),式(shi)(shi)中(zhong)n——導體(ti)的單(dan)線(xian)(xian)總(zong)根(gen)數(股數)
b、緊壓圓導體或扇形(xing)導體、瓦(wa)形(xing)導體
需要采取稱重截(jie)(jie)面法來測量(liang),在電線或電纜上截(jie)(jie)取導(dao)體(ti)(ti)長度1000mm(去(qu)除絕緣(yuan)的裸導(dao)體(ti)(ti)),用天平秤(cheng)秤(cheng)出重量(liang)值(zhi)(zhi)W,單位:g (克(ke)),再按照下(xia)列公式來計算出電纜導(dao)體(ti)(ti)的截(jie)(jie)面值(zhi)(zhi):
S=W/(ρ·L)=W(g)/[ρ(g/cm^3)*10^(-3)*1000(mm)]=W(g)/ρ(g/cm^3) (mm^2)
其中:ρ——導(dao)體材料比重,銅(tong)8.89(g/cm^3)、鋁 2.7(g/cm^3)注:稱(cheng)重截(jie)面(mian)法同樣適(shi)用(yong)于非緊(jin)壓導(dao)體的(de)截(jie)面(mian)積(ji)測(ce)量。
以上計算出的電纜導體的截面值只是用來與電纜標稱截面的參考比較。因為按照國家標準GB∕T 3956-2008《 電纜的導體》要求,只對導體的電阻率有嚴格要求,電阻不得大于標準要求的最大電阻值,即使電纜導體的截面積小于標稱值,只要是導體的電阻值是合格的(小于標準中規定的最大值)就可以認為導體是合格的。要保證導體的電阻合格,實際導體的截面積就不可能小得太多。
生產部